KY39/H - Bradford Road/Bronte Street

Showing comments and forms 1 to 3 of 3

Comment

Draft Bradford District Local Plan - Preferred Options (Regulation 18) February 2021

Representation ID: 28555

Received: 09/04/2021

Respondent: Bradford District Ward Councillor (Labour)

Representation Summary:

KY39/H in Keighley East, not Keighley Central.

Comment

Draft Bradford District Local Plan - Preferred Options (Regulation 18) February 2021

Representation ID: 28681

Received: 24/03/2021

Respondent: Environment Agency

Representation Summary:

Flood Zones 2, 3 and the current/draft 3b/3a(i) within site boundary - Site clips Flood Zone 2.

There is to be no development with the 3b/3a(i) extent unless considered water compatible or essential infrastructure. Where this is the case the development must demonstrate no increase in risk to others, no loss of Functional Floodplain and suitable mitigation measures for use and the lifetime of the development.

Development on site should follow a sequential layout so as to prevent unnecessary development within Flood Zones 3b, 3 and 2 wherever possible. If the site is considered Greenfield then surface water discharge rates post development should be restricted to the pre development Greenfield discharge rate.

If the site is considered Brownfield then there should be a 30% reduction in surface water discharges, or restricted to Greenfield rates, there should be no increase in brownfield surface water discharge rates post development. So as to support prevention of cumulative increases to flood risk and should be in line with SuDs design principles. Some SuDs principles such as storage ponds should not be solely relied upon within areas at risk of fluvial flooding as they may not be operational during a flood.

Development must be shown to be safe for the lifetime of the development. See the Adept Guidance of Access and Egress plans. Hazard ratings may need to be assessed as part of the proposal.

Mitigation such a proofing measures and raised Finished Floor Levels, must be set above the 1 in 100 plus Climate Change level for the site. Current Guidance is on .gov.

The applicant must ensure there is no increase in risk to others for the lifetime of the development (including climate change). Where on Greenfield sites compensatory storage must be actively sought.

Consideration must be made to making space for water and providing betterment in terms of flood risk management where ever possible. For development near ordinary watercourses we would recommend an 8 metre easement strip along the length of the riverbank, or a 45degree angle from the bed in the case of culverts, to be kept clear of permanent structures such as buildings. This is to maintain access to the riverbank for any improvements or maintenance. A Flood Defence Consent may be required for the LLFA for works in/affecting an ordinary watercourse.

For main rivers, we generally require an 8 metre easement strip along the length of the riverbank to be kept clear of permanent structures such as buildings, or a 45degree angle from the bed in the case of culverts. This is to maintain access to the riverbank for any improvements or maintenance. Environmental Flood Risk Activity Permits may be required for development near rivers.

It is likely these sites are going to show changes/increases in flood risk as a result of climate change.

The SFRA (to follow) is going to consider future flooding including future Functional Floodplain this may identify sites at more future risk than others which may affect its allocation or how development should be sequentially laid out on the site.

Object

Draft Bradford District Local Plan - Preferred Options (Regulation 18) February 2021

Representation ID: 29405

Received: 29/03/2021

Respondent: Historic England

Representation Summary:

Eastwood House in Victoria Park, a Grade II Listed Building, is located 150 metres west of the site. The development of this area could harm elements which contribute to the significance of this designated heritage asset. Whilst we welcome the inclusion of a reference to the proximity of this designated heritage asset as a Constraint in the sites pro forma, we consider that the third bullet point under the Development Considerations for this site should be amended to be worded more
positively. Whilst the park is undoubtedly part of the setting to Eastwood House it is not mentioned in the list description for this building. The pro forma for this site incorrectly refers to Grade II Listed Building north-west of the site as Victoria Park. This should be corrected so as to avoid any confusion.

a) Replace the third bullet point under the Development Considerations for this site with the following:
‘Consider the impact of development on the setting of the Grade II Eastwood House in Victoria Park and appropriately avoid/minimise any harm caused.’
b) Correct the references made in the site pro forma to the designated heritage asset north-west of the site from ‘Victoria Park’ to ‘Eastwood House in Victoria Park’